Hydraulics International  

Chatsworth,  CA 
United States
http://www.hiipumps.com
  • Booth: 8132


PORTABLE 4,500-psi O2 and 10,000-psi N2 Gas Booster Systems

Manufacturer and Designer of AIR and ELECTRIC Driven Booster System rated to 10,000-psi for Breathing Air/N2 and 4500-psi for Oxygen service. Ideal for filling or topping off cylinders, Nitrox and Trimix gas mixing and other dive market related applications. Each unit is capable of boosting from as low as 50-psi up to cylinder maximum pressure rating. Ideal for maximizing the use of the GAS in storage cylinders resulting in an increase in the number of complete SCUBA fills per storage cylinder. Reduces fill times by eliminating the need to cascade air storage cylinders. All products are Proudly made in the USA.


 Products

  • Miniature Air or Hand Driven Oxygen Gas Booster
    Miniature Air or Hand Driven Oxygen Gas Booster rated to 4350-psi (300 bar). Used for filling or topping off Rebreathers from as low as 100-psi (7 bar). Offered in 2-stage and double acting configurations....

  • Miniature Air or Hand Driven Oxygen Gas Booster rated to 4350-psi (300 bar). Used for filling or topping off Rebreather bottles from as low as 100-psi (7 bar). Offered in 2-stage and double acting configurations. Air Consumption with 100-psi drive operating at 60 cycles/min is less than 4.4-scfm. May be powered using a SCUBA cylinder or miniature 2-hp air compressor. 

  • Miniature Air or Hand Driven Oxygen Gas Booster
    Miniature Air or Hand Driven Oxygen Gas Booster rated to 4350-psi (300 bar) enclosed in a watertight case on wheels and retractable pull handle. Used for filling or topping off Rebreathers from as low as 300-psi (20 bar)....

  • Miniature Air or Hand Driven Oxygen Gas Booster rated to 4350-psi (300 bar) enclosed in a watertight case on wheels and retractable pull handle. Used for filling or topping off Rebreather bottles from as low as 100-psi (7 bar). Offered in 2-stage and double acting configurations. Air Consumption with 100-psi drive operating at 60 cycles/min is less than 4.4-scfm. May be powered using a SCUBA cylinder or miniature 2-hp air compressor.
  • Portable Oxygen Gas Booster System
    Portable Air Driven Gas Booster rated to 5000-psi (345 bar) for oxygen/helium and 10,000-psi (690 bar) for Breathing Air or Nitrogen. Used for filling or topping off Rebreathers and larger oxygen cylinders from as low as 200-psi (14 bar)....

  • Portable Air Driven Gas Booster rated to 5000-psi (345 bar) for oxygen/helium and 10,000-psi (690 bar) for Breathing Air or Nitrogen. Used for filling or topping off Rebreather bottles and larger oxygen cylinders from as low as 200-psi (14 bar). Offered in 2-stage, single acting and double acting configurations. Typical units include low and high pilot valves to automatically stop the booster, pressure relief valve, inlet & outlet filters (5-Micron), shop air controls (includes filter regulator, gauge and on/off ball valve), optional high pressure air controls (includes high pressure regulator, relief valve and outlet regulated gauge), and gas inlet & outlet gauges (dual scale).
  • Portable ELECTRIC Driven Oxygen Gas Booster
    Portable Electric Driven Gas Booster rated to 5000-psi (345 bar) for oxygen/helium and 10,000-psi (690 bar) for Breathing Air or Nitrogen. Used for filling or topping off Rebreathers and larger oxygen cylinders from as low as 200-psi (14 bar)....

  • Portable Electric Driven Gas Booster rated to 5000-psi (345 bar) for oxygen/helium and 10,000-psi (690 bar) for Breathing Air or Nitrogen. Used for filling or topping off Rebreather bottles and larger oxygen cylinders from as low as 200-psi (14 bar). Offered in 2-stage and double acting configurations. Unit uses NO BELTS or Pulleys, making it the quietest Electric driven gas booster in its class. Includes a 2-hp motor available in 115-VAC, 230-VAC, 380-VAC and 460-VAC. Standard units include low and high limit switches to automatically stop the booster, pressure relief valve, inlet & outlet filters (5-Micron), gas inlet & outlet gauges (dual scale), hour meter, and outlet shutoff and bleed valves.

  • 2-Bottle Mobile Hand Trolley
    2-Bottle Mobile Hand Trolley, includes an Air Driven Oxygen/Helium Gas Booster rated to 5000-psi (345 bar). Used for filling or topping off Rebreathers and larger oxygen cylinders from as low as 300-psi (21 bar)....

  • 2-Bottle Mobile Hand Trolley, includes an Air Driven Oxygen/Helium Gas Booster rated to 5000-psi (345 bar). Used for filling or topping off Rebreather bottles and larger oxygen cylinders from as low as 300-psi (14 bar). Offered in single and double acting configurations. Typical units include a high pressure pilot valves to automatically stop the booster, pressure relief valve, inlet & outlet filters (5-Micron), shop air controls (includes filter regulator, gauge and on/off ball valve) and high pressure air controls (includes high pressure regulator, relief valve and outlet regulated gauge), and gas inlet & outlet gauges (dual scale).